Comment by drob518
Set up time is needed before every clock edge to ensure reliable state transitions by traditional flip flops. It’s not a one time thing. When you’re operating at low voltages it’s more likely that random system noise will violate the stable level required during the setup time. That’s why they need to do this correction all the time.